- Test equipment
- Current generator with constant current
- Full automatic temperature rising and large curren
- Small current generator
- Large current generator
- AC / DC current generator
- Intelligent high current
- Three-phase current generator
- Intelligent three-phase current
- The three-phase voltage and current source
- Three frequency generator
- Fault indicator tester
- Fuse tester
- Transformer integrative tester
- Thermal relay tester
- Tester for motor protector
- Relay protection tester
- High voltage switchgear
- Low voltage switchgear
- AC and DC voltage tester
- DC high voltage generator
- DC breaker ampere second characteristic test instr
- Power inspection class
High voltage switch cabinet electricity test bench for manufacturers of high and low voltage Switchgear Factory operation debugging, can also be used to replace the DC operation power supply substation maintenance station and other places of the DC power supply. In power plant, substation, switch cabinet factory and other units, a device is important and secondary equipment is important, because a device and the second device constitute a whole, only when the two are in good condition, in order to ensure the safety of electricity production. Secondary equipment is refers to the condition of a device for monitoring, controlling and regulating, protection, operation personnel to provide conditions or production command signal equipment, and secondary circuit fault often damage or affect the electrical equipment in normal operation, and use a pipe of secondary circuit of electrical equipment, is to ensure that an important part of the electric power production safety. This test car is based on the two loop test and test requirements, starting from the company's own design and production from the actual needs of users of the two loop test.
This product has full function, small volume, beautiful appearance and convenient mobile features, is the ideal equipment for testing the parameters of the two device.
1, three-phase four wire AC voltage direct output;
2, three-phase alternating current (0~430V) voltage adjustable output;
3, three-phase AC voltage fixed (380V) output;
4 (0~20A/50V), three-phase AC current adjustable output (single-phase / three-phase switch);
5, single-phase DC output voltage can be adjusted (0~260V);
6, single-phase DC Direct switching output (110V/220V);
7, take the line into the power supply socket module
Single phase 10A 2 hole a hole of a three-phase single-phase 16A 3 25A 4 a hole