- Test equipment
- Current generator with constant current
- Full automatic temperature rising and large curren
- Small current generator
- Large current generator
- AC / DC current generator
- Intelligent high current
- Three-phase current generator
- Intelligent three-phase current
- The three-phase voltage and current source
- Three frequency generator
- Fault indicator tester
- Fuse tester
- Transformer integrative tester
- Thermal relay tester
- Tester for motor protector
- Relay protection tester
- High voltage switchgear
- Low voltage switchgear
- AC and DC voltage tester
- DC high voltage generator
- DC breaker ampere second characteristic test instr
- Power inspection class
Measuring device can also be programmed to detect equipment and low voltage switchgear, low voltage power distribution equipment, wire stringing bridge etc.. Test device has a variety of testing procedures in the preparation of the national standard, after the input parameters, the device can achieve a key to achieve a key detection. The user according to the measuring device can also be programmed to detect equipment and low voltage switchgear, low voltage power distribution equipment, wire stringing bridge etc.. Test device has a variety of testing procedures in the preparation of the national standard, after the input parameters, the device can achieve a key to achieve a key detection. Users in accordance with the requirements of the connected test line, click the program control button, the device can be automatically added to the rated current and voltage followed in accordance with national standards completed on all the detection equipment, such as contact resistance insulation and withstand voltage, analog power supply under the condition of mechanical and electrical protection device, response time, timing, lack of phase voltage loss of pressure test, switch action time, transformer protection environment simulation, test results, and the detection results to be displayed, stored and printed.
Measurement accuracy of the electric energy meter: the device can detect the whole function of the electric energy meter according to the national standard.
2) voltage, current, active power, reactive power, frequency, power factor, harmonic content, and other electrical parameters of the detection.
3) remote control operation (from the time of the instructions issued to the relay closed).
(4) remote signal detection (whether change and change time time).
5) voltage and voltage loss protection test.
6) temperature detection, gas sensor detection.
7) over current protection and grounding current protection.
8) switch amountshift simulation test.
9) program control detection of all items.
3 display function, the device uses a 8 inch color LCD touch screen, graphical interface, easy to learn, and to provide menu style help files.
4 automatic data entry function, the device can automatically identify and have memory function, as long as the user input model, automatic input parameters. Relevant test data can be stored in accordance with the user's requirements for a long time.
5 communication functions: a total of Ethernet port, infrared communication port, RS485 interface, RS232 interface, GPRS, CAN, carrier, Bluetooth interface. The interface adopts the common standard protocol, which is convenient for communication with all kinds of test equipment.
And to detect the communication protocol of the test equipment.
Amount of output | Frequency error less than <±0.01Hz Phase error <±0.2° Waveform distortion <±0.3%(基波) The time error is less <40µs Output frequency 0~1000Hz |
|
Electric source voltage | allowed band AC220V±10%,50Hz±10% | |
Environment temperature | Range of use 0~40℃ Storage area -20~70℃ |
|
Electric current source | Cross flow | Phase current output (RMS) 0~30A/相 Six and current output (RMS) 0~180A Allowable working value (RMS) for a long time. <=10A/相 Six and current 180A allows working hours <=10s Fine degree <±0.2% Load voltage <20V Maximum output power 250VA/相 Superposition of harmonic frequency 0~21次 |
Electric voltage source | Cross flow | Phase voltage output (RMS) 0~130V/相 Line voltage output (RMS) 0~260V Fine degree <±0.2% Maximum output power 70VA/相 Superposition of harmonic frequency 0~21次 |
Direct current | Output range 0~300V Fine degree <±0.2% Maximum output power 130VA |
|
Time measurement | Test range 0.1ms~3600s | |
Open off input | Null contact 1~20mA,24V(DC) Potential contact 0~250V(DC) |
|
Open off output | Null contact 250V/0.3A(DC) | |
Machine box volume | Length * width * height 360mm ×195mm ×380mm | |
Weight of machine box | Host weight 18kg |