- Test equipment
- Current generator with constant current
- Full automatic temperature rising and large curren
- Small current generator
- Large current generator
- AC / DC current generator
- Intelligent high current
- Three-phase current generator
- Intelligent three-phase current
- The three-phase voltage and current source
- Three frequency generator
- Fault indicator tester
- Fuse tester
- Transformer integrative tester
- Thermal relay tester
- Tester for motor protector
- Relay protection tester
- High voltage switchgear
- Low voltage switchgear
- AC and DC voltage tester
- DC high voltage generator
- DC breaker ampere second characteristic test instr
- Power inspection class
DDDL-4000JZ AC DC generator (referred to as the up flow reactor), developed by our company developed test equipment, which combines the advantages of similar products at home and abroad in a body, and adopts the technology of numerical control, anti-interference ability strong, and a generation of up flow is compared, due to the low power consumption and large capacity self coupling voltage converter and high permeability core, with the advantages of high output power, small volume, light weight, etc.. Mainly used for thermal relay, motor protector, contactor, breaker, air switch, switch cabinet, circuit breaker, protection screen check.
The built-in digital ammeter for direct reading
The high accuracy level 0.2
The big power, small volume, strong load ability
The test precision is high
(1) Name: SDDL-4000JZ AC and DC large current generator.
(2) the environmental groups: belong to GB6587.1-86 "electronic measuring instruments environmental tests program" in group III instrument (can) for use in an outdoor environment.
Input voltage: AC380V + 10%
Rated capacity: 20KVA
2.1 maximum output DC current value: 4000A, under the current sustainable work for 8 hours.
2.2 maximum output DC voltage value: 5V.
2.3 output current regulation: 0~4000A continuous adjustable.
DC:0-4000A AC:0-4000A
2.4 accuracy requirements:
Source: the effect is less than or equal to 0.3% ratings
Shi Piao: less than 1% of rated value
The temperature drift is less than 0.04% / C ratings:
Load effect: less than 1% ratings (output voltage change due only to the output current from zero to the rated value caused by changing rate)
Ripple voltage ratings: less than 1% +10mV.
2.5 line adjustment rate: 0.1%
Load adjustment rate: 0.1%
2.6 output display:
Display mode: voltage meter for 4 digit display
The current meter is 5 digit display
Display precision: voltage meter 0.1V
Current meter 0.1A
Display error: 1 words less than 0.2% meter.
1 words current meter is less than or equal to 0.2%.
2.7 equipment should be equipped with over voltage, over current, over temperature, lack of equal automatic protection.